LOAD CELL STC-100kg
FEATURES
• Capacities: 25 to 5000kg, 250 to 40Klb
• Alloy steel construction
• Stainless steel available
• Bi-direction(tension/compression)
• Rationalized output
• NTEP Class III 5000S, lllL10000 approval from 250lb to 20Klb
OPTIONAL FEATURE
• FM approval available
S Type load cell as the name indicated can be easily identified by S-shaped body. They can be loaded either in tension or compression, and used for single or multiple-cell application if the output is rationalized.
• Electro-mechanical conversion scales
• Silo/hopper/tank weighing
• Crane scales
• Fork-lift scales
• Dosing/filling
• Universal material tester
• Tensile/pulling force measurement
CAPACITY |
| L | W | W1 | H | T |
25/50/75kg | mm | 50.8 | 26.7 | 12.7 | 63.5 | M6 x 1.0 |
(inch) | 2.00 | 1.05 | 0.50 | 2.50 |
100/150kg | mm | 50.8 | 22.92 | 19.1 | 76.2 | M10 x 1.5 |
(inch) | 2.00 | 0.9 | 0.75 | 3.00 |
250/300lb | mm | 50.8 | 26.7 | 12.7 | 76.2 | 3/8-24UNF |
(inch) | 2.00 | 1.05 | 0.50 | 3.00 |
250kg 500/750lb | mm | 50.8 | 30.4 | 19.1 | 76.2 | M12 x 1.75 1/2-20UNF |
(inch) | 2.00 | 1.2 | 0.75 | 3.00 |
500/750kg | mm | 50.8 | 25.4 | 19.1 | 76.2 | M12 x 1.75 |
(inch) | 2.00 | 1.00 | 0.75 | 3.00 |
1K/1.5Klb | mm | 50.8 | 26.1 | 19.1 | 76.2 | 1/2-20UNF |
(inch) | 2.00 | 1.03 | 0.75 | 3.00 |
1000/1500kg 2K/2.5K/3Klb | mm | 50.8 | 31.8 | 25.4 | 76.2 | M12 x 1.75 1/2-20UNF |
(inch) | 2.00 | 1.25 | 1.00 | 3.00 |
5K/7.5Klb | mm | 76.2 | 31.8 | 25.4 | 107.9 | 3/4-16UNF |
(inch) | 3.00 | 1.25 | 1.00 | 4.25 |
2000/2500/5000kg | mm | 76.2 | 38.1 | 31.8 | 100.4 | M20 x 1.5 |
(inch) | 3.00 | 1.50 | 1.25 | 3.95 |
10Klb | mm | 88.9 | 31.8 | 25.4 | 120.7 | 3/4-16UNF |
(inch) | 3.50 | 1.25 | 1.00 | 4.75 |
15Klb | mm | 101.6 | 38.1 | 31.8 | 139.7 | 1-14UNS |
(inch) | 4 | 1.50 | 1.25 | 5.50 |
20Klb | mm | 127 | 55.7 | 50.8 | 177.8 | 11/4-12UNF |
(inch) | 5 | 2.19 | 2 | 7.00 |
40Klb | mm | 152.4 | 69.9 | 63.5 | 254.0 | 11/2-12UNF |
(inch) | 6.00 | 2.75 | 2.50 | 10.00 |
PARAMETER | VALUE | UNIT |
NTEP/OIML Accuracy class | NTEP III & IIIL | Non-Approved |
|
Maximum no. of intervals (n) | III 5000 single* IIIL 10000 single* | 2000 |
|
Y = Emax/Vmin | 10000 | 5000 | Maximum available |
Standard capacities (Emax) | 25, 50, 75, 100, 250, 500, 750, 1000, 1500, 2000, 2500, 5000 | kg |
Standard capacities (Emax) | 250, 300, 500, 750, 1K, 1.5K, 2K, 2.5K, 3K, 5K, 7.5K, 10K, 15K, 20K, 40K | lbs |
Rated output-R.O. | 3.0 | mV/V |
Rated output tolerance | 0.25 | ±% of rated output |
Zero balance | 1 | ±% of rated output |
Non linearity | 0.020 | 0.020 (SS: 0.05) | ±% of rated output |
Hysteresis | 0.020 | 0.020 (SS: 0.05) | ±% of rated output |
Non-repeatability | 0.020 | ±% of rated output |
Creep error (20 minutes) | 0.030 | ±% of rated output |
Zero return (20 minutes) | 0.030 | ±% of rated output |
Temperature effect on min. dead load output | 0.0015 | 0.0026 | ±% of rated output/°C |
Temperature effect on sensitivity | 0.0010 | 0.0015 | ±% of applied load/°C |
Compensated temperature range | -10 to +40 | °C |
Operating temperature range | -20 to +60 | °C |
Safe overload | 150 | % of R.C. |
Ultimate overload | 300 | % of R.C. |
Excitation, recommended | 10 | Vdc or Vac rms |
Excitation, maximum | 15 | Vdc or Vac rms |
Input impedance | 385±5 | Ohms |
Output impedance | 350±3 | Ohms |
Insulation resistance | >5000 | Mega-Ohms |
Construction | Nickel plated alloy steel** |
|
Environmental protection | IP67 |
|
* Capacities 250-20Klbs ** Stainless steel available
All specifications listed subject to change without notice.
FM Approval
Intrinsically Safe: Class I, II, III; Div. 1 Groups A-G Non-Incendive: Class I; Div. 2 Groups A-D